Push-Pull Detachable SC/APC FTTH Drop Patch Cord – 3×2mm Flat Cable, G657A2, LSZH

Rayoptic’s Push-Pull Detachable SC/APC FTTH Drop Patch Cord simplifies fiber installation through small wall openings. The detachable end is factory-terminated and supplied with its green SC/APC housing uninstalled, allowing the protected ferrule assembly to be pulled or pushed through holes as small as 4.5 mm. After routing, the housing is assembled on site without tools.Featuring a standard SC/APC connector at the opposite end and 3 × 2 mm white, UV-resistant LSZH flat cable with G.657.A2 bend-insensitive fiber, this assembly is designed for indoor and outdoor FTTH last-mile connections. Standard and custom lengths are available.

Product Overview

Simplify FTTH Cable Entry Through Small Wall Openings

Routing a pre-terminated fiber cable through a wall can require an opening large enough to accommodate a fully assembled connector. Rayoptic’s Push-Pull Detachable SC/APC FTTH Drop Patch Cord addresses this installation challenge with a compact, factory-terminated end and a separately supplied green connector housing.

At the detachable end, fiber termination is completed at the factory, while the green SC/APC housing remains uninstalled for delivery. The protected ferrule assembly can be pulled or pushed through a hole as small as 4.5 mm in diameter. Once the cable has passed through the wall, the installer fits the green housing around the assembly and snaps the cover into place without tools.

This push-through or pull-through installation method helps reduce the size of the required wall opening and simplifies on-site work. No fiber splicing or connector termination is required at the installation site.

The assembly features a detachable SC/APC connector at one end and a fully assembled standard SC/APC connector at the other. Insertion loss is below 0.3 dB per connector, and return loss is above 60 dB.

Connector tensile strength is 60 N, and the operating temperature range is −40°C to +70°C, supporting demanding last-mile installation environments.

Available lengths include 10, 20, 30, 40, 50 and 60 m. Custom lengths can be supplied to match specific cable routes and installation requirements.

Fetures

• Push-through or pull-through routing
The protected connector end can be pushed or pulled through wall openings during installation.

• Passes through 4.5 mm holes
The compact ferrule assembly fits through holes as small as 4.5 mm before the green SC/APC housing is installed.

• Factory-terminated, housing supplied separately
Optical termination is completed at the factory. The detachable end is delivered with its green housing uninstalled and ready for on-site assembly.

• Tool-free housing assembly
Fit the housing around the terminated assembly and snap the cover into place after routing.

• No on-site splicing or termination
Simplifies installation and helps reduce labor time and costs.

 

 

 

 

Technical Specification

Parameter-pull detaSpecification
Product TypePushchable FTTH drop patch cord
Connector AFactory-terminated detachable SC/APC; green housing supplied separately
Connector BFully assembled standard SC/APC
Connector PolishAPC at both ends
Fiber TypeG.657.A2 bend-insensitive single-mode fiber
Cable StructureFlat drop cable
Cable Dimensions3 × 2 mm
Outer Sheath MaterialLSZH
Sheath ColorWhite
UV ResistanceUV-resistant outer sheath
Available Lengths10, 20, 30, 40, 50 and 60 m; custom lengths available
Insertion Loss< 0.3 dB per connector
Return Loss> 60 dB
Connector Tensile Strength60 N
Operating Temperature−40°C to +70°C
Hole PassageProtected ferrule assembly passes through a 4.5 mm diameter hole before housing installation
Routing MethodPush-through or pull-through at the detachable end
On-Site AssemblyTool-free installation of the green SC/APC housing
On-Site Splicing or TerminationNot required
Installation EnvironmentIndoor and outdoor
Main ApplicationsFTTH subscriber drops, last-mile access and customer premises connections

Installation Overview

Push or Pull Through, Then Assemble

The detachable end is supplied with the green SC/APC housing uninstalled. Complete cable routing before assembling the housing.

  1. Route the protected end
    Push or pull the protected ferrule assembly through the wall opening. The compact end supports passage through holes as small as 4.5 mm.

  2. Align the ferrule assembly
    After routing, position the lower housing half with its open side facing upward. Locate the red alignment mark on the ferrule holder and keep it facing upward.

  3. Seat the assembly
    Place the ferrule assembly into the housing. Gently pull the cable backward while pressing the spring into position until the assembly is correctly seated.

  4. Close the housing
    Fit the upper housing cover and press it into place until it clicks securely.

Keep the ferrule protected during handling and housing assembly. Inspect and clean the connector end face before mating.

Application

• FTTH subscriber drop connections
• Last-mile fiber access networks
• Fiber cable entry through small wall openings
• Outdoor-to-indoor fiber transitions
• Residential and commercial premises installations
• Connections between fiber termination boxes, optical outlets and equipment with compatible SC/APC interfaces

Related Products

logo rayoptic comm
* We respect your privacy. When you submit your contact information, we agree to only contact you in accordance with our Privacy Policy.
TYPE TO SEARCH