Rayoptic Now Supplies SN-MT 12F and 16F Trunk and Breakout Cables in Production Quantities

Rayoptic Team

Rayoptic Team

Rayoptic Team brings over 15 years of industry experience in fiber optic connectivity solutions for FTTH, data center, and FTTA deployments. Our team shares practical product insights, installation guidance, and application knowledge covering fiber optic cables, connectors, terminals, distribution hubs, and network enclosures.

Rayoptic now supplies SN-MT 12F and 16F trunk cables and breakout cables in production quantities, expanding our fiber connectivity portfolio for high-density data center applications.

Our trunk cables feature SN-MT connectors at both ends. Our breakout cables feature an SN-MT connector at one end, with SN, CS, MDC, LC uniboot or SC uniboot connectors at the other. This range supports both multi-fiber trunk connections and fiber distribution to different connector interfaces.For customers moving from product evaluation to project deployment, Rayoptic offers a manufacturing source for SN-MT cable assemblies built to defined project requirements.

From Connector Technology to Cable Assemblies

In our earlier article, What Is an SN-MT Connector?, we introduced the connector technology and its role in high-density optical connectivity.SN-MT is a Very Small Form Factor (VSFF) multi-fiber connector developed by SENKO. Its compact design accommodates multiple fibers within a small footprint, helping increase connection density in space-constrained patching environments.When specifying a cable assembly, however, connector density is only part of the requirement. The assembly must also match the equipment interface, fiber count, polarity and cable routing.Rayoptic’s SN-MT trunk and breakout cable offerings address these practical connection needs.

SN-MT Trunk Cables: SN-MT Connectors at Both Ends

Rayoptic supplies trunk cables with SN-MT connectors at both ends, available in 12F and 16F configurations:
  • SN-MT 12F to SN-MT 12F
  • SN-MT 16F to SN-MT 16F
These assemblies provide multi-fiber connections between compatible SN-MT interfaces. They can connect compatible patch panels, cassettes and equipment interfaces while keeping multiple fibers organized within a common cable structure.Cable length, fiber type, jacket requirements, guide-pin configuration and polarity should be specified according to the intended installation.For trunk assemblies with multiple connector tails, the total cable fiber count and the fiber count of each SN-MT connector should be identified separately in the assembly drawing.

SN-MT Breakout Cables: Multiple Connector Options

Rayoptic also supplies breakout cables with an SN-MT 12F or 16F connector at one end and separate connector branches at the other.Available breakout-side connector options include:
  • SN connectors
  • CS connectors
  • MDC connectors
  • LC uniboot connectors
  • SC uniboot connectors
These assemblies distribute fibers from a compact SN-MT interface to separate connections, allowing the cable design to match different equipment ports and patching arrangements.
Cable FormatConnection Configuration
SN-MT trunk cableSN-MT 12F to SN-MT 12F, or SN-MT 16F to SN-MT 16F
SN-MT to SN breakout cableSN-MT 12F or 16F to SN connectors
SN-MT to CS breakout cableSN-MT 12F or 16F to CS connectors
SN-MT to MDC breakout cableSN-MT 12F or 16F to MDC connectors
SN-MT to LC uniboot breakout cableSN-MT 12F or 16F to LC uniboot connectors
SN-MT to SC uniboot breakout cableSN-MT 12F or 16F to SC uniboot connectors
The number of branches, branch lengths and fiber mapping should be defined for each assembly. These details help ensure that the breakout cable fits the intended routing and connects the correct fibers to the correct ports.

Choosing the Right SN-MT Cable Configuration

The choice between 12F and 16F should follow the equipment interface and network cabling design.Fiber count alone does not establish compatibility. The mating interface, adapter, connector polish, guide-pin configuration and polarity must also match the intended connection.For breakout cables, the connector type at the branch end is equally important. Selecting SN, CS, MDC, LC uniboot or SC uniboot connectors depends on the ports being connected and the available installation space.Suitability for a particular network speed also depends on the complete optical link, including the transceiver, fiber type and optical architecture. Each assembly should therefore be specified against the actual interface requirements.

Key Details to Include in Your Inquiry

To help Rayoptic review your configuration and prepare a quotation, please provide:
  • Cable format: trunk or breakout
  • SN-MT fiber count: 12F or 16F
  • Total cable fiber count: including the number of SN-MT connector tails, where applicable
  • SN-MT connector configuration: male or female guide-pin requirements
  • Breakout-side connector type: SN, CS, MDC, LC uniboot or SC uniboot
  • Fiber type and connector polish
  • Cable jacket and diameter requirements
  • Overall cable length
  • Number of breakout branches and branch lengths
  • Polarity or fiber mapping drawing
  • Required insertion loss and return loss
  • Order quantity and target delivery date
An assembly drawing is particularly helpful for reviewing connector orientation, branch identification and fiber assignments before production.

Discuss Your SN-MT Connectivity Requirements with Rayoptic

Rayoptic’s SN-MT 12F and 16F trunk and breakout cables are now available for bulk supply.Whether your project requires SN-MT connections at both ends or a breakout assembly to SN, CS, MDC, LC uniboot or SC uniboot interfaces, send us your assembly drawing or project specification to discuss the required configuration, pricing and production schedule.Email: sales@rocfttx.comExplore Rayoptic SN-MT Fiber Connectivity

For more details, please visit www.rayopticcom.com;