Pullable Preterminated SCAPC Drop Cable 3.0mm TPU FTTH
Tags:Preterminated SCAPC, FTTH drop cable, Pullable SCAPC, Fiber Optical SCAPC Connector, FTTH Network, MDU Network
Highlights
Rotating Head
The bullet head is designed rotating to protect F.O. cable not to be twisted and avoid traction cap being rotating off during installation.

Blind-assembling
SC inner housing can be blind-assembly. Not need to find key point based on APC 8º angle polishing during field assembly.

Removable & Repeatable assembly
SC inner housing is designed easily to assembly and remove.

Efficient Cable Laying-Out Package
The preterminated drop cable be coiled on cardboard drum.Save installation time.

Specification
| Technical Parameters of Connector | |
| Item | Parameters |
| Connector A | Pullabe SCAPC |
| Connector B | Normal SCAPC |
| Insertion Loss (dB) | Typical <0.15, Max<0.3 |
| Return Loss (dB) | >60 |
| Pulling Force of Connector A | 150N |
| Size of Pullable SCAPC Connector | Length:47.5mm/ O.D. Max:5.5mm |
| Flam Retardant Rating | UL94 V-0 |
| Operation Temperature | -40~+70℃ |
Fiber Optic Cable Cross-section

Technical Parameters of fiber optic cable | |||
Optical Fiber | Category | ITU-T G.657.B3 | ITU-T Recommendation G.657.B3 |
Fiber Count | 1 | ||
Coating Color | Blue | ||
O.D. | 250±15μm | ||
Semi-tight buffer | Color | Blue | |
Material | LSZH | ||
O.D. | 880±20μm | ||
Outer Sheath | Material | FRTPU-UV resistant | |
Thickness | 0.65±0.05mm | ||
Color | Black | ||
Strength Member | Material | High modulus aramid yarns | |
Count | 7*1580 dtex | ||
Cable | O.D. | 3.0 +0.0mm,-0.2mm | |
Weight | 10Kg/Km | ||
Tensile Strength | 800N | IEC 60794-1-21-E1 | |
Crush Resistance | 5N/mm, 3 cycles | IEC 60794-1-21-E3A | |
Min.Bending Radius | 10XD(Static) 20XD(Dynamic) | IEC 60794-1-21-E11A | |
Attenuation under torsion at 180° | 0.10dB | IEC 60794-1-21-E7 | |
Span | 80m | ||
Installation span | 1% | ||
Maximum wind speed | 80km/h | ||
Operation Temperature Range | -40~+70℃ | IEC 60794-1-22-F1 | |
Environmental Parameters
Parameter Test Method Conditions
Temperature Change IEC61300-2-22 High Temperature: +75°C
GR-326-CORE Lowest Temperature: -40°C
168 Hours, 21 cycles

Features
- Pre-connectorized in factory, stability and reliability
- Low IL Loss, High Reflection
- 100% Tested in Factory
Application
- FTTH Access Network;
- Drop;
- Last mile;
- MDU Network;
Pullable SC Connector Assembly Instruction

What is Pullable SCAPC Fiber Optic Patchcord?
A pullable SC/APC fiber optic patch cord is a type of fiber optic cable that features SC/APC connectors and is designed to be easily pulled through conduits or other pathways during installation. Here’s a breakdown of its components and characteristics:
SC/APC Connectors
- SC (Subscriber Connector): A standard fiber optic connector with a push-pull latching mechanism, known for its ease of use and reliable performance.
- APC (Angled Physical Contact): The connector end-face is polished at an 8-degree angle, which minimizes back reflections and insertion loss, making it ideal for applications requiring high precision and low signal loss.
Pullable Design
- Pullable Feature: The cable is designed to be pulled through conduits, ducts, or other pathways without damage. It usually has a robust construction with additional strength members or a reinforced jacket to withstand the pulling forces.
- Ease of Installation: This design simplifies installation in environments where the cable needs to be routed through complex pathways, reducing the risk of damage during the process.
Applications
- FTTH (Fiber to the Home): Commonly used in FTTH deployments where the fiber needs to be routed from the distribution point to individual residences.
- Data Centers: Useful in data centers for connecting equipment across large distances where the cables need to be pulled through cable management systems.
- Telecommunications Networks: Employed in various network environments where long cable runs are required, such as between different floors of a building or across campus settings.
Advantages
- Durability: Designed to withstand the physical stress of being pulled through conduits.
- Low Signal Loss: The APC polish reduces back reflection, maintaining high signal quality over long distances.
- Versatility: Suitable for a wide range of installation environments, from residential to commercial and industrial applications.
Example Use Case
In a multi-story building, a pullable SC/APC fiber optic patch cord could be used to connect the main distribution frame in the basement to an optical network terminal on an upper floor. The pullable design ensures the cable can be routed through existing conduits without being damaged, while the SC/APC connectors provide reliable and low-loss connections at both ends.
In summary, a pullable SC/APC fiber optic patch cord is a specialized cable designed for ease of installation in challenging environments, offering durable construction and high-performance connectivity for various fiber optic applications.